|  Z512, Z522 Digital / Analog   Mass Flow Controller / Meter   SEC-Z512MGX SEC-Z522MGXN SEC-Z522MGX   SEC-Z512X SEC-Z522XN SEC-Z522X   SEF-Z512MGX SEF-Z522MGXN SEF-Z522MGX   SEF-Z512X SEF-Z522XN SEF-Z522X   Full-scale flow rate MR/MG number   (N2 conversion flow rate) #R01:10SCCM   #R1.5:17.5SCCM   #01:30SCCM   #1.5:55SCCM   #02:100SCCM   #2.5:175SCCM   #03:300SCCM   #3.5:550SCCM   #04:1SLM   #4.5:1.75SLM   #05:3SLM   #5.5:5.5SLM   #06:10SLM   Valve Type   Flow rate at fully closed control valve   Flow rate control range   Flow rate measuring range (SEF)   Operating temperature   Response   Linearity   Repeatability   50 to 300 kPa (d)   #5.5, #06: 100 to 300 kPa (d)   Operating differential pressure (SEF)   MAX. Operating pressure   Pressure resistance   Leak Integrity   Flow rate setting signal   Flow rate output signal   Wetted materials   1/4 inch VCR equivalent   Option: 1.125 inch IGS   Mounting orientation   *1 The gas type and full scale settings for the SEC(SEF)-Z512MGX, Z522MGX, and Z522MGXN can be changed   by the operator, using special software.   *2 The flow rate precision guaranteed temperatures conform to SEMI E56-1296 standards. The precision is that   associated with the full-scale MR and MG number values.   *3 IGS: Integrated Gas System   * SCCM and SLM are notations indicating the gas flow rate (mL/min, L/min, at 0°C and 101.3 kPa).   Mass flow controller model *1 SEC-Z512KX   Mass flow meter model *1 SEF-Z512KX   O: Normally open C: Normally closed   ≤ 2% F.S.   2-100% of F.S.   1/2SCCM   MR/MG number   #6.5: 22SLM   #07: 30SLM   #08: 50SLM   0-100% of F.S.   Accuracy *2 ±1.0%F.S. ±1.0%S.P.(Flow rate>25%F.S.)   ±0.25%F.S.(Flow rate≤25%F.S.)   5 to 50°C (recommended temperature range: 15 to 45°C)   ≤ 1 second: Over full flow rate range   ≤ ±0.5% F.S.   ≤ ±0.2% F.S.   Operating differential pressure 50 to 300 kPa (d) 200 to 300 kPa (d)   ≤ 300 kPa (d)   450 kPa (g)   1000 kPa (g)   ≤ 5 x 10-12 Pa·m3/s (He)   0.1 to 5 V DC (2% to F.S.); Input impedance 1 MÙ or higher   0 to 5 V DC (0% to F.S.); Minimum load resistance 2 kÙ or higher   Digital interface   With address function: RS-485 (transmission speed 38,400 bps)   F-Net Protocol   316L Stainless Steel (polished surface)   Power supply   +15V±5% 150mA   -15V±5% 150mA   Signal response   Analog: D-Sub 9-pin (TOP)   Digital: 2 LAN jacks (TOP)   Standard Fitting *3   1/4 inch VCR equivalent   Option: 1.125 inch IGS, 1.5 inch IGS   1.5 inch IGS   Free   Z512/522 Web Ver.001   Subject to change without notice. |